FKS 1DP-PBM-E Meter for Air Pressure, Speed and Flow Measurements

Measures Speed and Diff / Gage Pressure

FlowKinetics FKS 1DP-PBM-E meter

The FKS 1DP-PBM-E is a digital manometer and air speed meter that sets new standards for ease of use due to its prompt driven user interface and intuitive operation. It is ideally suited for general pressure measurement, airflow monitoring, testing and balancing, speed traverses, HVAC, process control, stack testing, R & D, pressure measurements across fans, filters, etc.

US Flag Designed and Assembled in the USA

Features

Specifications

Dimensions

5.7 in × 3.6 in × 1.8 in (14.5 cm × 9.1 cm × 4.5 cm)

Weight

0.67 lb (0.305 kg) excluding batteries

Working Temperatures

Operating: 32°F to 122°F (0°C to 50°C)

Storage: 14°F to 140°F (-10°C to 60°C)

Power supply

2 × 9V Alkaline batteries (life: approx. 40hours) or optional wall adapter (WPA) available as an accessory

Pressure

For available pressure ranges see ordering information

Measures True Differential, Static and Gauge Pressure using a fully temperature compensated sensor.

Zero offset and zero temperature shift: eliminated through auto-zero

Accuracy at 25°C: Typically within ±0.1% of full scale pressure (±0.22% max)

Maximum simultaneous pressure on both ports for each sensor (above ambient):

  • 10 psi for sensors with a range of ±5 inH2O or below.
  • 15 psi for sensors with a range of ±12 inH2O or above.

Speed

For available speed ranges see ordering information

Corrected by user-defined flow pressure and temperature.

Using an optional speed probe with user selectable flow coefficient

Accuracy at 25°C: Typically within ±0.24% of full scale speed

K factor

Probe coefficient set by user. Range: 0.00 to 9.99

Density correction

Set by user (temperature and pressure)

Damping

Automatic and adaptive. User selectable exponential smoothing or averaging

Display

2-line variable contrast alphanumeric LCD

Pressure units

Pa, kPa, inH2O, mmHg, inHg, psi, mbar and lb/ft2

Speed units

m/sec, ft/sec and ft/min

Compatible Mediums

Clean, dry, non-corrosive, non-flammable gases

Output

RS232 serial port interface, 9-pin connector. USB adapter (USBA2) available as an accessory.

Warranty

One year parts and labor.

Ordering Information & Accessories

All prices are given in USD and are subject to change without notice. Please contact us about applicable discounts.

FKS 1DP-PBM-E meter
FKS 1DP-PBM-E meter

FKS 1DP-PBM-E -

Select Range:


Medium: Air at 20°C, 101.325 kPa Change...
Probe: Pitot-Static Change...
  • Measure pressure, speed (with optional probe), and flow (using probe survey)
  • One differential pressure transducer
  • Protective rubber enclosure
  • Printed manual
  • Tubing
  • NIST-traceable calibration with data
  • Lead time: 2 weeks
$605.00

Quantity:

Accessories & Parts

Speed and Flow probes

FKT series meter is compatible with all the Pitot-Static, S-type, RAP and Kiel probes we offer.

Click here to see available probes.

Meter Part Number Description Price

FKS 1DP-PBM-E-0.25

FKS 1DP-PBM-E Multi-Function Meter

Differential pressure range: ±0.25 inH2O (±62 Pa)

Speed range: 0.3 to 10.2 m/s or 50 to 2004 ft/min

$605.00

FKS 1DP-PBM-E-1

FKS 1DP-PBM-E Multi-Function Meter

Differential pressure range: ±1 inH2O (±248 Pa)

speed range: 0.5 - 20.4 m/sec or 100 - 4009 ft/min

$605.00

FKS 1DP-PBM-E-4

FKS 1DP-PBM-E Multi-Function Meter

Differential pressure range: ±4 inH2O (±995 Pa)

Speed range: 1 to 40.6 m/s or 200 to 8018 ft/min

$605.00

FKS 1DP-PBM-E-12

FKS 1DP-PBM-E Multi-Function Meter

Differential pressure range: ±12 inH2O (±2986 Pa)

Speed range: 1.7 to 70.5 m/s or 347 to 13887 ft/min

$575.00

FKS 1DP-PBM-E-20

FKS 1DP-PBM-E Multi-Function Meter

Differential pressure range: -4 to +20 inH2O (-995 Pa to +4977 Pa)

Speed range: 2.3 to 91.0 m/s or 448 to 17928 ft/min

$575.00
Accessory Description Price

PBM-WPA

Auto-switching power supply (100V-240V AC 50-60Hz)

US plug included

$40.00
Plug-EUR European plug for power supply $7.00
Plug-UK UK plug for power supply $7.00
Plug-AUST Australian plug for power supply $7.00

SwiftScan

Real time software for continuous monitoring of pressure and speed using Microsoft Excel

6 ft serial cable included

$95.00
CABLE6 Serial cable replacement - 6ft (1.8m) $10.00
CABLE50 50ft (15.2m) serial cable. $30.00
USBA USB to serial adapter for computers with no serial port. Length: 1ft (30cm). Windows 98/2000/ME/XP. $25.00

Probes

Needed if you are measuring speed

Link

Filter Kit Set of two 10-micron filters with replaceable elements. Includes a pack of 10 replacement filter elements. Useful for protecting the instrument in dirty environments. $50.00

All prices are given in USD.

Specifications and prices are subject to change without notice.

Please contact us about applicable discounts.

Email:
inform@flowkinetics.com

Tel: (979) 680-0659

Tel: (888) 670-1927

Fax: (979) 680-0659

Mailing Address:
FlowKinetics LLC
4700 Shoal Creek Dr.
College Station, TX 77845
USA

Copyright © 2001-2024 • FlowKinetics™ LLC. • All rights reserved. • Privacy PolicySite Map

Medium:

Temperature: (-200 to 1250 °C)

Pressure: (2 to 30 psi absolute)

Select test configuration and dimensions.

Round Duct:

Diameter (D):

Rectangular Duct:

Width (W):

Height (H):

Open Area:

Max Insertion (H):

Duct or mounting wall thickness (if any):

Select probe that you want to use to measure speed or flow.

Note: Probes are not included with the meters. They are available separately and should be selected according to your requirements. Contact us if you need assistance selecting the right probe for your application.


Pitot-Static Probe

General use for determining point flow speed and flow rates from speed surveys

More details...

Rapid Averaging Probe (RAP)

Designed for quickly measuring average flow speed or flow rates in ducts

More details...

S-Type Probe

Designed for measuring speed in dirty flows such as smoke stacks.

More details...

Kiel Probe

Total pressure probe designed to measure speed where the direction of flow changes considerably during testing

More details...

Select this if you want to use your own probe.

Flow coefficient =

Corrected Speed=flow coefficient × Uncorrected Speed

--------